Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRSC

    · Air transport possible
    · Uses CO2 refrigerant (R744)
    · Greatly reduced GWP
    · Eliminates the need to pay for F-Gas recovery & disposal
    · Eliminates the need for periodic inspections based on the Fluorocarbon Emissions Control Act (Japan)
SeriesSet temperature rangeCooling capacityTemperature stabilityCooling methodCirculating fluid
HRSC012?0605 to 40℃1.3kW to 5.9kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%)
HRSC0905 to 40℃9.5kW,11kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%), Deionized water
HRSC1005 to 35℃10.5kW,11.5kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%), Deionized water

Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC

    ?Non F-Gas
    ?Uses CO2 Refrigerant (R744)
    ?Greatly reduced GWP
    ?GWP = 1 Compliant with each country’s refrigerant regulations
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
     ? “GWP” indicates the global warming potential. The values are based on
     the IPCC AR4.
    ?Air transport possible
    ?Eliminates the need to pay for F-Gas recovery & disposal
    ?Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC
    Manual
    Series View search result
    HRZCView search result
  • Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC
    DoC
    Series View search result
    HRZCView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
HRZC?20 to 90℃10 kW±0.1℃Water-cooled
refrigeration
Fluorinated fluids
60% ethylene glycol aqueous solution
Deionized water/Tap water

Non F-Gas Uses (CO2 Refrigerant) Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043

    ?Non F-Gas (CO2 refrigerant R744)
    ?GWP: 1 (Natural refrigerant)
    ?EU refrigerant regulations: GWP150 or less?
    ?US refrigerant regulations: GWP700 or less?
    ?California, US refrigerant regulations: GWP750 or less
     ?As of December 2023
    ?Air transport possible
     No air transport restrictions for non-toxic and non-flammable?
     refrigerants
     ?A1 (ASHRAE34 standard)
    ?No F-Gas management required
     Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
    ?No F-Gas recovery & disposal costs
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Non F-Gas Uses (CO2 Refrigerant) Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043
    DoC
    Series View search result
    INR-495-042
    INR-495-043
    View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
INR-495-042
INR-495-043
-20 to 708.5 kW±1.0℃Water-cooled
refrigeration
Fluorinated fluid

[Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF

    ?Low GWP Refrigerant Chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?No heater is required, as the circulating fluid is heated using only the heat
     exhausted by the refrigerating circuit.
    ?Compatible with power supplies in Europe, Asia, Oceania, and North,
     Central, and South America
    ?3-phase 400 VAC Low-noise design 70 dB(A)
    ?Outdoor installation IPX4
  • [Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF
    Manual
    Series Cooling capacity View search result
    HRSF012 to 0601.3 kW, 1.9 kW, 2.4 kW,
    3.2 kW, 5.9 kW (60 Hz)
    View search result
SeriesSet temperature
range
Cooling capacityTemperature
stability
Cooling methodCirculating fluid
HRSF012 to 0605 to 40℃1.3 kW, 1.9 kW, 2.4 kW,
3.2 kW, 5.9 kW (60 Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
15 to 40% Ethylene glycol aqueous solution
Deionized water

[Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF150/200

    ?Low GWP Refrigerant Chiller
     GWP: 146?  ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?No heater is required, as the circulating fluid is heated using only the heat
     exhausted by the refrigerating circuit.
    ?Compatible with power supplies in Europe, Asia, Oceania, and North,
     Central, and South America
    ?3-phase 400 VAC Low-noise design 70 dB(A)
    ?Outdoor installation IPX4
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • [Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF150/200
    Manual
    Series Cooling capacity View search result
    HRSF150
    HRSF200
    15.7kW
    20.5kW (Air-cooled)
    20.6kW (Water-cooled)
    View search result
SeriesSet temperature rangeCooling capacityTemperature
stability
Cooling methodCirculating fluid
HRSF150
HRSF200
5 to 35℃15.7kW
20.5kW (Air-cooled)
20.6kW (Water-cooled)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
15 to 40% Ethylene glycol aqueous solution
Deionized water

[Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF

    · Low GWP refrigerant chiller
     GWP:146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    · Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    · More effective energy-saving is achieved through use of a DC inverter
     compressor and an inverter pump.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • [Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF
    Manual
    Series Cooling capacity View search result
    HRZF01010kWView search result
  • [Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF
    DoC
    Series Cooling capacity View search result
    HRZF01010kWView search result
SeriesSet temperature rangeCooling capacityTemperature stabilityCooling methodCirculating fluid
HRZF010-20?90℃10kW±0.1℃Water-cooled refrigerationFluorinated fluids, 60% ethylene glycol aqueous solution

[Low GWP Refrigerant Chiller] Thermo-chiller/Rack Mount Type HRRF

    ?Low GWP refrigerant chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?Operable without the need to remove the unit from the rack
     Front access: Simple to control, service, and maintain with all filters and
     drainage accessible via the front panel
    ?Space saving: Multiple chillers can be mounted to a 19-inch rack.
    ?Cooling capacity: 1.2/1.8 kW (60 Hz)
    ?Temperature stability: ±0.1°C
    ?Power supply: Single-phase 200 to 230 VAC (50/60 Hz)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesSet temperature rangeCooling capacityTemperature
stability
Cooling methodCirculating fluid
HRRF0125 to 35℃1.0kW/1.2kW
(50/60Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water,
15% ethylene glycol aqueous solution
HRRF0185 to 35℃1.6kW/1.8kW
(50/60Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water,
15% ethylene glycol aqueous solution

[Low GWP Refrigerant Chiller] Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRLF

    ?Low GWP refrigerant chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?Temperatures for 2 fluid channel systems can be controlled individually
     by one chiller.
    ?Space saving, Reduced wiring
    ?Touch panel
     Numeric keypad inputs
     Notice for alarms and maintenance
     Temperature waveform can be displayed.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRLF200-A-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 19 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Air-cooled refrigerationTap water,
Deionized water
HRLF200-W-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 21.5 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Water-cooled refrigerationTap water,
Deionized water

Go Top

天美传媒精品1区2区3区| 日韩乱码一区二区三区中文字幕| 美女日逼视频免费| 找个日韩操逼的看看| 国产免费无码一区二区视频无码| 枫花恋精品一区二区久久| 色999日韩自偷自拍美女| 爱男爽高潮鸡穴视频| 精品一区二区av天堂色偷偷| 美女肏肏逼应用下载| 日韩精品人妻一区二区免费| 美女大鸡操很多水在线看| 午夜性无码视频在线播放| 日本一区二区不卡在线国产| 欧美一区亚洲一区视频在线观看| 国产污污污在线观看视频| 国产美女裸体视频全免费| 中文字幕欧美人妻在线| 男生插女生下面流出白色精液视频| 国奴精品毛片av一区二区三区| 女教师色色天天免费播放| 99热这里只有精品98| 手机成人三级a在线观看| 九九视频精品只有这里有| 97人人澡人人爽人人揉| 中文字幕人妻一区二区三区人妻| 冷色系的发色有哪些颜色| 日本不卡高清视频在线播放| 日本免费精品一区二区三区四区| 国产精品毛片无遮挡高清| 欧美一区二区三区高清性群p| 精品一区二区三区乱码中文字幕| 色噜噜AV亚洲色一区二区| 国产伦精品一区二区三区福利| 中国熟女色av夜夜嗨| 亚洲国产日韩欧美高清片| 男的日女生批网页| 中文字幕在线视频一区二区| 最新免费高清无码片| 尤物性生活午夜在线视频| 日韩人妻无码中字一区二区|